Global Testing Laboratory is fully equipped with proper machinery and modernized instruments. All the tests are done under supreme guidance and with proper safety and precautions. All the laboratory environment requirements are fulfilled as per the concern standards.

GTL is accredited for testing Cables in accordance with the specified requirements mentioned in the National and International Standards, such as:

We provide complete testing of electrical & IT related products. This ensures customers are able to comply with the widest range of International standards and end-user requirements.It has well qualified and trained analysts for its operations. This section provides electrical analysis within specified time and to the satisfaction of the customers.

Testing Facilities and Products

GTL offers one stop solution for testing of all DIETY(Department of Electronics and Information Technology) notified products to meet the growing demand for IT and customer electronic products where manufacturers need faster, accurate, and efficient services to meet the requirement as per Indian/International Standards.

Complete testing facility for various types of product such as:

PVC insulated (heavy duty) electric cables Part-1 for working voltage up to and including 1100 volts as per IS 1554 (P-1)1988
PVC insulated cablesfor working voltage up to and including 1100 volts
Aluminiumbars,plates and rods
M.S. Pipe and Tubes
Aerial Bunched Cables for rated voltage up to and including 1100v as per IS 14255-1995
Cross-linked Polyethylene Insulated PVC Sheathed Cables for working voltage up to and including 1100v as per IS 7098 (P-1)1988-
Aluminium conductors for overhead transmission purpose
Aluminium conductors galvanized steel reinforced
M. S. conduit pipe.
Plug & Socket outlet of rated voltage up to and including 250 volts and rated current up to and including 16 amperes as per IS 1293-2019
Pressure sensitive adhesive insulating tapes for electric purpose as per IS 7098(P-3/Sec -1)1986
Rigid Flexible PVC Conduit Pipe as per IS 9537-1988
Rigid Steel Conduit pipe as per IS 9537-1988
Switches for domestic and similar purpose as per IS 3854-1997
Steel pipe,CastIron pipe, Ductile Iron pipe,G. I. pipe, S. W. pipes, Hubbless pipe and fittings etc
Steel conduit pipe
S.S.Plate/Sheet, Strip Chequered plate etc.
CRC Sheets and strips
Immersion water heater
Pump-sets and Motors
Meter box
G. I. Box
Fan Box
Insulating rubber Mat
Electrical panels
MCB/RCB
MCB Box
Sun mica sheet for switches
Bulb holders
Junction Box
Earthing rods and strips
G. I. and Copper Strips for Earthing etc.
Enameled winding wires
Conduit fittings (bends, sockets, caps, etc.)
PVC INSULATED UNSHEATHED/SHEATHED CABLES WITH RIGID AND FLEXIBLE CONDUCTOR FOR RATED VOLTAGE UPTO AND INCLUDING 1100 VOLTS.
Product’s is conducted according to IS, ASTM, IEC ISO, DIN, BS /MTNL / RDSO or any other international standard.The laboratory is highly equipped with advance machinery, applicable for every parameters of test..

Testing services:

AC high voltage test
Thermal stability test
Conductor resistance test
Elongation test
Elongation at break
Tensile test for conductor
Wrapping test & Brinell
Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc
Carbon black content
Carbon black dispersion
Environmental stress cracking
High voltage test
Oxidation Induction Time (Differential Scanning calorimeter)
Insulation resistance test (IR/VR)
Shrinkage test
Test for PE insulation
Melt flow index
Vicat softening point
Water absorption test
Annealing test for copper
Loss of mass in air oven
Ageing in air oven
Armour dimension diameter
Cold bend test
Cold impact test
Dimensions
Torsion test for round wire
Heat shock test
Hot deformation test
Making and breaking capacity
Creepage distances and clearance distances
Flexible cable and their connection
Test for overall dimension test
Uniformity of zinc coating
Force necessary to withdraw the plug
Operation of earthing contacts
Winding test for formed wireHigh voltage dc (water immersion) test
Making and breaking capacity
Lay ratio test
Earthing resistance etc.
Protection against electric shock
Insulation resistance and electric strength test
Persulphate test (tinned copper conductor cable)
Provision for earthing
Protection against electric shock
High voltage dc (water immersion) test
Interlocked socket outlet
Mechanical strength
Construction of fixed socket outlet
Lay ratio test
Resistance to burning
Resistance to humidity
Insulation resistance and electric strength test
Creepage distances and clearance distances
Flexible cable and their connection
Termite resistance test
Weathering tests
Torsion test for round wire
Temperature rise
Provision for earthing
Weathering tests
Uniformity of zinc coating
Resistance to rusting
Mass of zinc coating
Resistance to burning
Construction of fixed socket outlet
Force necessary to withdraw the plug
Resistance to rusting
Adhesion to backing
Adhesion to backing
Winding test for formed wire
Interlocked socket outlet
Termite resistance test
Mechanical strength
Operation of earthing contacts
Persulphate test (tinned copper conductor cable)
Compression test
Bending test
Resistance to heat
Temperature rise
Earthing resistance etc.
Resistance to heat
Collapse test
Adhesion to steel
Adhesion to steel
Terminal
Breaking load test
Hot set test
Flammability test
Thermal Endurance (Cable Service life)
UV resistance test -XENON
Bending test
Resistivity
Resistivity
Collapse test
Bending test
Compression test
Test for overall dimension test
Resistance to humidity
Electrolytic corrosion test